{"product_id":"woo-e9b694b7-sma-sunny-boy-smart-energy-sbse5-8-us-50-5-8kw-hybrid-inverter-67211","title":"SMA Sunny Boy Smart Energy SBSE5.8-US-50 5.8kW Hybrid Inverter","description":"\u003ch2\u003eSMA SBSE5.8-US-50 Sunny Boy Smart Energy Hybrid Inverter\u003c\/h2\u003e\n\u003cp\u003eThe SMA SBSE5.8-US-50 Sunny Boy Smart Energy is a versatile hybrid inverter, ideal for residential solar systems. It combines a PV inverter with a battery inverter, offering efficient energy management and storage solutions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200% DC\/AC design capability for flexible installation and system sizing.\u003c\/li\u003e\n\u003cli\u003eIntegrated SunSpec Certified RSD transmitter for rapid commissioning.\u003c\/li\u003e\n\u003cli\u003eSmart energy management with SMA ShadeFix optimization and SMA 360° app.\u003c\/li\u003e\n\u003cli\u003eCompact, lightweight design for easy mounting and space-saving.\u003c\/li\u003e\n\u003cli\u003e10-year warranty, extendable to 25 years for long-term reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnology and Overview\u003c\/h2\u003e\n\u003cp\u003eThis inverter uses SMA's innovative technology, including SMA ShadeFix and SMA Smart Connected, to ensure maximum power output and system reliability.\u003c\/p\u003e\n\u003ch2\u003eInstallation and Compatibility Overview\u003c\/h2\u003e\n\u003cp\u003eWith its user-friendly design, the SBSE5.8-US-50 ensures straightforward installation and is compatible with a wide range of residential solar applications.\u003c\/p\u003e\n\u003ch2\u003eBenefits and Applications Overview\u003c\/h2\u003e\n\u003cp\u003eDesigned for energy savings and ease of use, the Sunny Boy Smart Energy hybrid inverter is perfect for homeowners looking to optimize their solar investment and achieve energy independence.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"128\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel No.\u003c\/td\u003e\n\u003ctd\u003eSBSE5.8-US-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV array power (200% oversizing)\u003c\/td\u003e\n\u003ctd\u003e11520 Wp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC voltage\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated MPP voltage range\u003c\/td\u003e\n\u003ctd\u003e136 V - 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. \/ Startup DC Voltage\u003c\/td\u003e\n\u003ctd\u003e60 V \/ 66 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. usable current input per MPPT\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. short-circuit current input per MPPT\u003c\/td\u003e\n\u003ctd\u003e30 A (the sum at all inputs must not exceed 60 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndependent MPPT inputs \/ inputs per MPPT\u003c\/td\u003e\n\u003ctd\u003e3 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection of MPPT inputs in parallel\u003c\/td\u003e\n\u003ctd\u003eA and B*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eBYD Battery-Box Premium HVL 12.0, 16.0, 20.0, 24.0, 28.0, 32.0 (UL9540)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage range\u003c\/td\u003e\n\u003ctd\u003e90 V to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. charging current \/ max. discharging current\u003c\/td\u003e\n\u003ctd\u003e30 A \/ 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of independent battery inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. charging power \/ max. discharging power\u003c\/td\u003e\n\u003ctd\u003e10000 W \/ 6063 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. apparent AC power\u003c\/td\u003e\n\u003ctd\u003e5760 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Rated power (at 240 V, 60 Hz)\u003c\/td\u003e\n\u003ctd\u003e5760 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Rated power (at 208 V, 60 Hz)\u003c\/td\u003e\n\u003ctd\u003e4992 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage rated and range\u003c\/td\u003e\n\u003ctd\u003e240 V (211 V to 264 V) or 208 V (183 V to 229 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC grid frequency \/ range\u003c\/td\u003e\n\u003ctd\u003e60 Hz \/ 55 Hz to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. rated output current\u003c\/td\u003e\n\u003ctd\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker (overcurrent protection)\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor at rated power\u003c\/td\u003e\n\u003ctd\u003e1 \/ adjustable 0.8 overexcited to 0.8 underexcited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. efficiency\u003c\/td\u003e\n\u003ctd\u003e98.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEC efficiency (240\/208V)\u003c\/td\u003e\n\u003ctd\u003e97.5% \/ 97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC disconnect \/ DC reverse polarity protection\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC AFCI arc-fault protection\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround fault monitoring \/ Grid monitoring\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC short circuit current capability\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll-pole-sensitive residual-current monitoring unit\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category grid \/ battery \/ PV\u003c\/td\u003e\n\u003ctd\u003eIII \/ II \/ II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W \/ H \/ D) \/ Weight\u003c\/td\u003e\n\u003ctd\u003e19.7 x 23.1 x 9.3 in \/ 38.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e?13 °F to +140 °F (?25 °C to +60 °C) with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology \/ cooling method\u003c\/td\u003e\n\u003ctd\u003eTransformerless \/ Natural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental protection rating\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ Type 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication protocols\u003c\/td\u003e\n\u003ctd\u003eModbus (SMA, SunSpec), Speedwire \/ Webconnect, SMA Battery Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces: WLAN \/ Ethernet \/ BAT-CAN \/ RS-485\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.4 GHz WLAN\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet ports \/ Number of outputs\u003c\/td\u003e\n\u003ctd\u003e2 \/ 1 (Multi function relay 30 Vdc \/1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty: 10 \/ (+5 \/ +10 \/ +15 years)\u003c\/td\u003e\n\u003ctd\u003eStandard feature \/ (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificates and approvals\u003c\/td\u003e\n\u003ctd\u003eUL 1741 SB\/SA, UL 62109-1, UL 1998, UL 1699B Ed. 1, UL9540, IEEE1547, FCC Part 15 (Class A \u0026amp; B), CAN CSA-C22.2, CA Rule 21, HECO Rule 14H, PV Rapid Shutdown System Equipment in accordance with UL1741, NEC 2020, NEC 2023 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMA Smart Connected\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMA ShadeFix (integrated shade optimization)\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSunSpec certified transmitter (Rapid Shutdown)\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (at 120 V, 60 Hz)\u003c\/td\u003e\n\u003ctd\u003e1920 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. apparent AC power\u003c\/td\u003e\n\u003ctd\u003e1920 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC voltage\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC grid frequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActivation mode\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Elegant Habitat","offers":[{"title":"Default Title","offer_id":44631473782871,"sku":"USIN100-0516","price":1199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/5754\/0183\/files\/PROD_Image_USIN100-0516_2024-02-26_SBSE5.8-US-50_SMA_Solar-1.jpg?v=1794248470","url":"https:\/\/firehabitat.com\/products\/woo-e9b694b7-sma-sunny-boy-smart-energy-sbse5-8-us-50-5-8kw-hybrid-inverter-67211","provider":"Elegant Habitat","version":"1.0","type":"link"}